Dwelling Space Standards - SUMMARY

 0    42 フィッシュ    sim
mp3をダウンロードする 印刷 遊びます 自分をチェック
 
質問 答え
Dwelling Space Standards
Single storey dwelling (4 bed 6 person = 99sq.m) Two storey dwelling (4 bed 6 person = 107sq.m) Three storey dwelling (4 bed 6 person = 113sq.m)
学び始める
Standardy Mieszkaniowych standartów
gross internal area
For dwellings designed for more than 6 people, at least 10sq.m. gross internal area should be provided for each additional person.
学び始める
Powierzchnia wewnętrzna brutto
accommodate
Dwelling plans should demonstrate that dwellings will accommodate the furniture, access and activity space requirements relating to the declared level of occupancy.
学び始める
pomieścić
Circulation in the home
The minimum width of hallways and other circulation spaces inside the home should be 900mm. This may reduce to 750mm
学び始める
Krążenie w domu
doorway
Minimum clear opening width of doorway (mm) = 750
学び始める
wejście
Living / dining / kitchen
The following combined floor areas for living / kitchen / dining space should be met: 2 person = 23sq.m. 3 person = 25sq.m. 4 person= 27sq.m. 5 person= 29sq.m. 6 person= 31sq.m.
学び始める
Salon / jadalnia / kuchnia
occupancy
Designed level of occupancy
学び始める
ilość osób
sitting area
The minimum width of the main sitting area should be 2.8m in 2-3 person dwellings and 3.2m in dwellings designed for four or more people.
学び始める
miejsce do siedzenia
three or more bedrooms
Dwellings with three or more bedrooms should have two living spaces, for example a living room and a kitchen-dining room. Both rooms should have external windows.
学び始める
trzy lub więcej sypialni
three or more bedrooms
Both rooms should have external windows. If a kitchen is adjacent to the living room, the internal partition between the rooms should not be load-bearing, to allow for reconfiguration as an open plan arrangement.
学び始める
trzy lub więcej sypialni
adjacent to
学び始める
przylegający
load-bearing wall
the internal partition between the rooms should not be load-bearing, to allow for reconfiguration as an open plan arrangement.
学び始める
ściana nośna
wheelchair
There should be space for turning a wheelchair in dining areas and living rooms and basic circulation space for wheelchairs elsewhere
学び始める
wózek inwalidzki
entrance level
A living room, living space or kitchen dining room should be at entrance level
学び始める
Poziom wejściowy
Bedrooms AREA
The minimum area of a single bedroom should be 8 sq m. The minimum area of a double or twin bedroom should be 12 sq m.
学び始める
OBSZAR sypialnie
Bedrooms WIDTH
The minimum width of double and twin bedrooms should be 2.75m in most of the length of the room.
学び始める
Sypialnie Szerokość
convenient temporary bed space
In homes of two or more storeys with no permanent bedroom at entrance level=, there should be space on the entrance level that could be used as a convenient temporary bed space
学び始める
wygodna tymczasowa sypialnia
ceiling hoist
Structure above a main bedroom and an accessible bathroom should be capable of supporting a ceiling hoist and the design should allow for a reasonable route between this bedroom and bathroom
学び始める
podnośnik sufitowy
hoist
学び始める
podnośnik
Bathrooms and WCs
Dwellings designed for an occupancy of five or more people should provide a minimum of one bathroom with WC and one additional WC.
学び始める
Łazienki i toalety
Bathrooms and WCs
Where there is no accessible bathroom at entrance level=, a wheelchair accessible WC with potential for a shower to be installed should be provided at entrance level
学び始める
Łazienki i toalety
Private open space
A minimum of 5 sq m of private outdoor space should be provided for 1-2 person dwellings and an extra 1 sq m should be provided for each additional occupant.
学び始める
Prywatna otwarta przestrzeń
balconies
The minimum depth and width of all balconies and other private external spaces is 1500mm.
学び始める
balkony
habitable
the designer should demonstrate how good levels of ventilation, daylight and privacy will be achieved in each habitable room and the kitchen.
学び始める
mieszkalny
Floor to ceiling heights
The minimum floor to ceiling height in habitable rooms is 2.5m between finished floor level and finished ceiling level.
学び始める
Wysokość od podłogi do sufitu
desirable
A minimum floor to ceiling height of 2.6m in habitable rooms is considered desirable
学び始める
pożądany
encouraged to do something
taller ceiling heights are encouraged in ground floor dwellings.
学び始める
zachęca do zrobienia czegoś
Daylight and sunlight
Glazing to all habitable rooms should be not less than 20% of the internal floor area of the room.
学び始める
Światło i słońce
stair providing easy access
In the Lifetime Homes Criteria a stair providing easy access is defined as one having maximum risers of 170mm, minimum goings of 250mm and a minimum width of 900mm measured 450mm above the pitch line.
学び始める
schody zapewnia łatwy dostęp
double loaded
double loaded (they serve dwellings on each side)
学び始める
podwójnie obciążony
Entrance and approach
All main entrances to houses, ground floor flats and communal entrance lobbies should be visible from the public realm and clearly identified.
学び始める
Wejście i podejście
communal entrance lobbies
学び始める
komunalne hole wejściowe
public realm
All main entrances to houses, ground floor flats and communal entrance lobbies should be visible from the public realm and clearly identified.
学び始める
sfera publiczna
gently sloping
The approach to all entrances should preferably be level or gently sloping
学び始める
łagodnie opadający
be level
The approach to all entrances should preferably be level or gently sloping
学び始める
być na poziomie
illuminated
All entrances should be illuminated and, have level access over the threshold
学び始める
oświetlony
threshold
All entrances should be illuminated and, have level access over the threshold
学び始める
próg
Entrance doors
Entrance doors should have 300mm of clear space to the pull side, and clear minimum opening widths of 800mm or 825mm depending on the direction and width of approach.
学び始める
Drzwi zewnętrzne
pull side
Entrance doors should have 300mm of clear space to the pull side, and clear minimum opening widths of 800mm or 825mm depending on the direction and width of approach
学び始める
odstęp z boku
external landing
Main entrances should have weather protection and a level external landing.
学び始める
Zewnętrzne podest
Communal
学び始める
wspólne / społeczne
Evidence Summary
Summary of evidence on proposed housing design standards for the Examination in Public of the draft replacement London Plan
学び始める
Podsumowanie dowodów